1.
Clinics in Orthopedic Surgery ; : 82-86, 2013.
Article in English | WPRIM | ID: wpr-88114

ABSTRACT

A twenty-year-old male visited our clinic with wrist and long finger metacarpophalangeal (MP) joint pain. Dynamic ultrasonography revealed sagittal band (SB) ulnar subluxation and extensor carpi ulnaris (ECU) volar subluxation. Magnetic resonance imaging showed longitudinal splitting and dislocation of the volar half slip of the ECU tendon. The redundant radial SB was augmented and ECU sheath was advanced to the periosteum using suture anchors. He was able to perform his previous activities at the last follow-up. We encountered a case of "simulateous" ECU dislocation with extensor tendon subluxation of the long finger at the MP joint. Therefore, we report this case with a review of the relevant literature.


Subject(s)
Humans , Male , Young Adult , Finger Injuries/diagnosis , Magnetic Resonance Imaging , Tendon Injuries/diagnosis , Ultrasonography
2.
The Journal of Advanced Prosthodontics ; : 10-15, 2011.
Article in English | WPRIM | ID: wpr-67270

ABSTRACT

PURPOSE: This study investigated the influence of bone quality and surgical technique on the implant stability quotient (ISQ) value. In addition, the influence of interfacial bone quality, directly surrounding the implant fixture, on the resonance frequency of the structure was also evaluated by the finite element analysis. MATERIALS AND METHODS: Two different types of bone (type 1 and type 2) were extracted and trimmed from pig rib bone. In each type of bone, the same implants were installed in three different ways: (1) Compaction, (2) Self-tapping, and (3) Tapping. The ISQ value was measured and analyzed to evaluate the influence of bone quality and surgical technique on the implant primary stability. For finite element analysis, a three dimensional implant fixture-bone structure was designed and the fundamental resonance frequency of the structure was measured with three different density of interfacial bone surrounding the implant fixture. RESULTS: In each group, the ISQ values were higher in type 1 bone than those in type 2 bone. Among three different insertion methods, the Tapping group showed the lowest ISQ value in both type 1 and type 2 bones. In both bone types, the Compaction groups showed slightly higher mean ISQ values than the Self-tapping groups, but the differences were not statistically significant. Increased interfacial bone density raised the resonance frequency value in the finite element analysis. CONCLUSION: Both bone quality and surgical technique have influence on the implant primary stability, and resonance frequency has a positive relation with the density of implant fixture-surrounding bone.


Subject(s)
Bone Density , Finite Element Analysis , Ribs